diff options
author | Ido Schimmel <idosch@mellanox.com> | 2015-10-15 17:43:29 +0200 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2015-10-15 23:27:57 -0700 |
commit | 5cd16d8c78fd17520fff437256f0c3a4e960fd5d (patch) | |
tree | cec72dd135a148ae1f1588299011a1d5334d954d | |
parent | 801bd3defb2eac756e6570168d0f8187781ad8ad (diff) |
mlxsw: cmd: Update CONFIG_PROFILE command documentation
The meaning of certain parameters in the profile passed to the device
during initialization has changed, so update their documentation
accordingly.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r-- | drivers/net/ethernet/mellanox/mlxsw/cmd.h | 24 |
1 files changed, 11 insertions, 13 deletions
diff --git a/drivers/net/ethernet/mellanox/mlxsw/cmd.h b/drivers/net/ethernet/mellanox/mlxsw/cmd.h index 27e48b426db5..c7889f4fa0d7 100644 --- a/drivers/net/ethernet/mellanox/mlxsw/cmd.h +++ b/drivers/net/ethernet/mellanox/mlxsw/cmd.h @@ -570,7 +570,7 @@ MLXSW_ITEM32(cmd_mbox, config_profile, set_max_vlan_groups, 0x0C, 6, 1); */ MLXSW_ITEM32(cmd_mbox, config_profile, set_max_regions, 0x0C, 7, 1); -/* cmd_mbox_config_profile_set_fid_based +/* cmd_mbox_config_profile_set_flood_mode * Capability bit. Setting a bit to 1 configures the profile * according to the mailbox contents. */ @@ -651,12 +651,8 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_vlan_groups, 0x28, 0, 12); MLXSW_ITEM32(cmd_mbox, config_profile, max_regions, 0x2C, 0, 16); /* cmd_mbox_config_profile_max_flood_tables - * Maximum number of Flooding Tables. Flooding Tables are associated to - * the different packet types for the different switch partitions. - * Note that the table size depends on the fid_based mode. - * In SwitchX silicon, tables are split equally between the switch - * partitions. e.g. for 2 swids and 8 tables, the first 4 are associated - * with swid-1 and the last 4 are associated with swid-2. + * Maximum number of single-entry flooding tables. Different flooding tables + * can be associated with different packet types. */ MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4); @@ -667,12 +663,14 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4); */ MLXSW_ITEM32(cmd_mbox, config_profile, max_vid_flood_tables, 0x30, 8, 4); -/* cmd_mbox_config_profile_fid_based - * FID Based Flood Mode - * 00 Do not use FID to offset the index into the Port Group Table/Multicast ID - * 01 Use FID to offset the index to the Port Group Table (pgi) - * 10 Use FID to offset the index to the Port Group Table (pgi) and - * the Multicast ID +/* cmd_mbox_config_profile_flood_mode + * Flooding mode to use. + * 0-2 - Backward compatible modes for SwitchX devices. + * 3 - Mixed mode, where: + * max_flood_tables indicates the number of single-entry tables. + * max_vid_flood_tables indicates the number of per-VID tables. + * max_fid_offset_flood_tables indicates the number of FID-offset tables. + * max_fid_flood_tables indicates the number of per-FID tables. */ MLXSW_ITEM32(cmd_mbox, config_profile, flood_mode, 0x30, 0, 2); |