diff options
author | Bjorn Helgaas <bhelgaas@google.com> | 2012-09-13 08:41:01 -0600 |
---|---|---|
committer | Bjorn Helgaas <bhelgaas@google.com> | 2012-09-13 08:41:01 -0600 |
commit | 78890b5989d96ddce989cde929c45ceeded0fcaf (patch) | |
tree | 4e2da81fc7c97f11aee174b1eedac110c9a68b3a /arch/arm/mach-tegra | |
parent | 1959ec5f82acbdf91425b41600f119ebecb5f6a8 (diff) | |
parent | 55d512e245bc7699a8800e23df1a24195dd08217 (diff) |
Merge commit 'v3.6-rc5' into next
* commit 'v3.6-rc5': (1098 commits)
Linux 3.6-rc5
HID: tpkbd: work even if the new Lenovo Keyboard driver is not configured
Remove user-triggerable BUG from mpol_to_str
xen/pciback: Fix proper FLR steps.
uml: fix compile error in deliver_alarm()
dj: memory scribble in logi_dj
Fix order of arguments to compat_put_time[spec|val]
xen: Use correct masking in xen_swiotlb_alloc_coherent.
xen: fix logical error in tlb flushing
xen/p2m: Fix one-off error in checking the P2M tree directory.
powerpc: Don't use __put_user() in patch_instruction
powerpc: Make sure IPI handlers see data written by IPI senders
powerpc: Restore correct DSCR in context switch
powerpc: Fix DSCR inheritance in copy_thread()
powerpc: Keep thread.dscr and thread.dscr_inherit in sync
powerpc: Update DSCR on all CPUs when writing sysfs dscr_default
powerpc/powernv: Always go into nap mode when CPU is offline
powerpc: Give hypervisor decrementer interrupts their own handler
powerpc/vphn: Fix arch_update_cpu_topology() return value
ARM: gemini: fix the gemini build
...
Conflicts:
drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
drivers/rapidio/devices/tsi721.c
Diffstat (limited to 'arch/arm/mach-tegra')
-rw-r--r-- | arch/arm/mach-tegra/board-harmony-power.c | 32 |
1 files changed, 17 insertions, 15 deletions
diff --git a/arch/arm/mach-tegra/board-harmony-power.c b/arch/arm/mach-tegra/board-harmony-power.c index 8fd387bf31f0..b7344beec102 100644 --- a/arch/arm/mach-tegra/board-harmony-power.c +++ b/arch/arm/mach-tegra/board-harmony-power.c @@ -51,7 +51,7 @@ static struct regulator_init_data ldo0_data = { .consumer_supplies = tps658621_ldo0_supply, }; -#define HARMONY_REGULATOR_INIT(_id, _name, _supply, _minmv, _maxmv) \ +#define HARMONY_REGULATOR_INIT(_id, _name, _supply, _minmv, _maxmv, _on)\ static struct regulator_init_data _id##_data = { \ .supply_regulator = _supply, \ .constraints = { \ @@ -63,21 +63,22 @@ static struct regulator_init_data ldo0_data = { .valid_ops_mask = (REGULATOR_CHANGE_MODE | \ REGULATOR_CHANGE_STATUS | \ REGULATOR_CHANGE_VOLTAGE), \ + .always_on = _on, \ }, \ } -HARMONY_REGULATOR_INIT(sm0, "vdd_sm0", "vdd_sys", 725, 1500); -HARMONY_REGULATOR_INIT(sm1, "vdd_sm1", "vdd_sys", 725, 1500); -HARMONY_REGULATOR_INIT(sm2, "vdd_sm2", "vdd_sys", 3000, 4550); -HARMONY_REGULATOR_INIT(ldo1, "vdd_ldo1", "vdd_sm2", 725, 1500); -HARMONY_REGULATOR_INIT(ldo2, "vdd_ldo2", "vdd_sm2", 725, 1500); -HARMONY_REGULATOR_INIT(ldo3, "vdd_ldo3", "vdd_sm2", 1250, 3300); -HARMONY_REGULATOR_INIT(ldo4, "vdd_ldo4", "vdd_sm2", 1700, 2475); -HARMONY_REGULATOR_INIT(ldo5, "vdd_ldo5", NULL, 1250, 3300); -HARMONY_REGULATOR_INIT(ldo6, "vdd_ldo6", "vdd_sm2", 1250, 3300); -HARMONY_REGULATOR_INIT(ldo7, "vdd_ldo7", "vdd_sm2", 1250, 3300); -HARMONY_REGULATOR_INIT(ldo8, "vdd_ldo8", "vdd_sm2", 1250, 3300); -HARMONY_REGULATOR_INIT(ldo9, "vdd_ldo9", "vdd_sm2", 1250, 3300); +HARMONY_REGULATOR_INIT(sm0, "vdd_sm0", "vdd_sys", 725, 1500, 1); +HARMONY_REGULATOR_INIT(sm1, "vdd_sm1", "vdd_sys", 725, 1500, 1); +HARMONY_REGULATOR_INIT(sm2, "vdd_sm2", "vdd_sys", 3000, 4550, 1); +HARMONY_REGULATOR_INIT(ldo1, "vdd_ldo1", "vdd_sm2", 725, 1500, 1); +HARMONY_REGULATOR_INIT(ldo2, "vdd_ldo2", "vdd_sm2", 725, 1500, 0); +HARMONY_REGULATOR_INIT(ldo3, "vdd_ldo3", "vdd_sm2", 1250, 3300, 1); +HARMONY_REGULATOR_INIT(ldo4, "vdd_ldo4", "vdd_sm2", 1700, 2475, 1); +HARMONY_REGULATOR_INIT(ldo5, "vdd_ldo5", NULL, 1250, 3300, 1); +HARMONY_REGULATOR_INIT(ldo6, "vdd_ldo6", "vdd_sm2", 1250, 3300, 0); +HARMONY_REGULATOR_INIT(ldo7, "vdd_ldo7", "vdd_sm2", 1250, 3300, 0); +HARMONY_REGULATOR_INIT(ldo8, "vdd_ldo8", "vdd_sm2", 1250, 3300, 0); +HARMONY_REGULATOR_INIT(ldo9, "vdd_ldo9", "vdd_sm2", 1250, 3300, 1); #define TPS_REG(_id, _data) \ { \ @@ -119,9 +120,10 @@ static struct i2c_board_info __initdata harmony_regulators[] = { int __init harmony_regulator_init(void) { + regulator_register_always_on(0, "vdd_sys", + NULL, 0, 5000000); + if (machine_is_harmony()) { - regulator_register_always_on(0, "vdd_sys", - NULL, 0, 5000000); i2c_register_board_info(3, harmony_regulators, 1); } else { /* Harmony, booted using device tree */ struct device_node *np; |