summaryrefslogtreecommitdiff
path: root/include
diff options
context:
space:
mode:
authorJens Axboe <axboe@kernel.dk>2018-06-01 07:39:48 -0600
committerJens Axboe <axboe@kernel.dk>2018-06-01 07:39:48 -0600
commit84e92c131a0a2c7b28d1aa98c69350bc3577f34c (patch)
tree07f9792e69984b41a6f030b7b9b180d2d13beed4 /include
parent131d08e122eaabae028378c0b4da688eb044c6af (diff)
parent30d90964e7b80a0723921e8b464c5ceda7297a7b (diff)
Merge branch 'nvme-4.18' of git://git.infradead.org/nvme into for-4.18/block
Pull NVMe changes from Christoph: "Below is another set of NVMe updates for 4.18. Besides the usual bug fixes this includes more feature completness in terms of AEN and log page handling on the target." * 'nvme-4.18' of git://git.infradead.org/nvme: nvme: use the changed namespaces list log to clear ns data changed AENs nvme: mark nvme_queue_scan static nvme: submit AEN event configuration on startup nvmet: mask pending AENs nvmet: add AEN configuration support nvmet: implement the changed namespaces log nvmet: split log page implementation nvmet: add a new nvmet_zero_sgl helper nvme.h: add AEN configuration symbols nvme.h: add the changed namespace list log nvme.h: untangle AEN notice definitions nvmet: fix error return code in nvmet_file_ns_enable() nvmet: fix a typo in nvmet_file_ns_enable() nvme-fabrics: allow internal passthrough command on deleting controllers nvme-loop: add support for multiple ports nvme-pci: simplify __nvme_submit_cmd nvme-pci: Rate limit the nvme timeout warnings nvme: allow duplicate controller if prior controller being deleted
Diffstat (limited to 'include')
-rw-r--r--include/linux/nvme.h16
1 files changed, 14 insertions, 2 deletions
diff --git a/include/linux/nvme.h b/include/linux/nvme.h
index 4112e2bd747f..2950ce957656 100644
--- a/include/linux/nvme.h
+++ b/include/linux/nvme.h
@@ -436,10 +436,19 @@ enum {
enum {
NVME_AER_ERROR = 0,
NVME_AER_SMART = 1,
+ NVME_AER_NOTICE = 2,
NVME_AER_CSS = 6,
NVME_AER_VS = 7,
- NVME_AER_NOTICE_NS_CHANGED = 0x0002,
- NVME_AER_NOTICE_FW_ACT_STARTING = 0x0102,
+};
+
+enum {
+ NVME_AER_NOTICE_NS_CHANGED = 0x00,
+ NVME_AER_NOTICE_FW_ACT_STARTING = 0x01,
+};
+
+enum {
+ NVME_AEN_CFG_NS_ATTR = 1 << 8,
+ NVME_AEN_CFG_FW_ACT = 1 << 9,
};
struct nvme_lba_range_type {
@@ -747,6 +756,7 @@ enum {
NVME_LOG_ERROR = 0x01,
NVME_LOG_SMART = 0x02,
NVME_LOG_FW_SLOT = 0x03,
+ NVME_LOG_CHANGED_NS = 0x04,
NVME_LOG_CMD_EFFECTS = 0x05,
NVME_LOG_DISC = 0x70,
NVME_LOG_RESERVATION = 0x80,
@@ -755,6 +765,8 @@ enum {
NVME_FWACT_ACTV = (2 << 3),
};
+#define NVME_MAX_CHANGED_NAMESPACES 1024
+
struct nvme_identify {
__u8 opcode;
__u8 flags;