summaryrefslogtreecommitdiff
path: root/include
diff options
context:
space:
mode:
Diffstat (limited to 'include')
-rw-r--r--include/linux/cpu_cooling.h18
-rw-r--r--include/linux/energy_model.h3
-rw-r--r--include/linux/thermal.h11
3 files changed, 9 insertions, 23 deletions
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index bae54bb7c048..b74732535e4b 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -33,6 +33,13 @@ cpufreq_cooling_register(struct cpufreq_policy *policy);
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
+/**
+ * of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
+ * @policy: cpufreq policy.
+ */
+struct thermal_cooling_device *
+of_cpufreq_cooling_register(struct cpufreq_policy *policy);
+
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *
cpufreq_cooling_register(struct cpufreq_policy *policy)
@@ -45,21 +52,12 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
{
return;
}
-#endif /* CONFIG_CPU_THERMAL */
-#if defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL)
-/**
- * of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
- * @policy: cpufreq policy.
- */
-struct thermal_cooling_device *
-of_cpufreq_cooling_register(struct cpufreq_policy *policy);
-#else
static inline struct thermal_cooling_device *
of_cpufreq_cooling_register(struct cpufreq_policy *policy)
{
return NULL;
}
-#endif /* defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL) */
+#endif /* CONFIG_CPU_THERMAL */
#endif /* __CPU_COOLING_H__ */
diff --git a/include/linux/energy_model.h b/include/linux/energy_model.h
index 73f8c3cb9588..d249b88a4d5a 100644
--- a/include/linux/energy_model.h
+++ b/include/linux/energy_model.h
@@ -9,7 +9,6 @@
#include <linux/sched/topology.h>
#include <linux/types.h>
-#ifdef CONFIG_ENERGY_MODEL
/**
* em_cap_state - Capacity state of a performance domain
* @frequency: The CPU frequency in KHz, for consistency with CPUFreq
@@ -40,6 +39,7 @@ struct em_perf_domain {
unsigned long cpus[0];
};
+#ifdef CONFIG_ENERGY_MODEL
#define EM_CPU_MAX_POWER 0xFFFF
struct em_data_callback {
@@ -160,7 +160,6 @@ static inline int em_pd_nr_cap_states(struct em_perf_domain *pd)
}
#else
-struct em_perf_domain {};
struct em_data_callback {};
#define EM_DATA_CB(_active_power_cb) { }
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index e45659c75920..d9111aebb97d 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -544,15 +544,4 @@ static inline void thermal_notify_framework(struct thermal_zone_device *tz,
{ }
#endif /* CONFIG_THERMAL */
-#if defined(CONFIG_NET) && IS_ENABLED(CONFIG_THERMAL)
-extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,
- enum events event);
-#else
-static inline int thermal_generate_netlink_event(struct thermal_zone_device *tz,
- enum events event)
-{
- return 0;
-}
-#endif
-
#endif /* __THERMAL_H__ */