diff options
author | Len Brown <len.brown@intel.com> | 2020-11-10 13:00:00 -0800 |
---|---|---|
committer | Len Brown <len.brown@intel.com> | 2020-11-10 11:40:57 -0500 |
commit | 949dd0104c496fa7c14991a23c03c62e44637e71 (patch) | |
tree | a90cbfb8ceb195e7160105a272122f97bab99980 /tools/power | |
parent | 3d7772ea5602b88c7c7f0a50d512171a2eed6659 (diff) |
powercap: restrict energy meter to root access
Remove non-privileged user access to power data contained in
/sys/class/powercap/intel-rapl*/*/energy_uj
Non-privileged users currently have read access to power data and can
use this data to form a security attack. Some privileged
drivers/applications need read access to this data, but don't expose it
to non-privileged users.
For example, thermald uses this data to ensure that power management
works correctly. Thus removing non-privileged access is preferred over
completely disabling this power reporting capability with
CONFIG_INTEL_RAPL=n.
Fixes: 95677a9a3847 ("PowerCap: Fix mode for energy counter")
Signed-off-by: Len Brown <len.brown@intel.com>
Cc: stable@vger.kernel.org
Diffstat (limited to 'tools/power')
0 files changed, 0 insertions, 0 deletions